§ 44-17. Construction standards for residential structures (except coastal high-hazard areas).  


Latest version.
  • A. 
    Elevation. The following standards apply to new and substantially improved residential structures located in areas of special flood hazard, in addition to the requirements in § 44-15B, Subdivision proposals, and § 44-15C, Encroachments, and § 44-16, Construction standards for all structures.
    (1) 
    Within Zones A1-A30, AE and AH, and also Zone A if base flood elevation data are available, new construction and substantial improvements shall have the lowest floor (including basement) elevated to or above two feet above the base flood elevation.
    (2) 
    Within Zone A, when no base flood elevation data are available, new and substantially improved structures shall have the lowest floor (including basement) elevated at least three feet above the highest adjacent grade.
    (3) 
    Within Zone AO, new and substantially improved structures shall have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as two feet above the depth number specified in feet on the community's Flood Insurance Rate Map enumerated in § 44-7 (at least two feet if no depth number is specified).
    (4) 
    Within Zones AH and AO, adequate drainage paths are required to guide floodwaters around and away from proposed structures on slopes.